Trusted HVAC Services in Blacklick, OH
Sears Heating and Cooling is proud to be your trusted partner for HVAC service in Blacklick, OH, and surrounding neighborhoods. We pride ourselves on delivering personalized heating and AC solutions tailored to the needs of Blacklick homeowners. Whether it’s a scorching summer day or a chilly winter night, count on us to keep your home at the perfect temperature. Reach out to us at 614-475-1800 or fill out our contact form to schedule service and discover the Sears Heating and Cooling difference.
Cooling Services
- AC Repairs: Our skilled technicians are equipped to diagnose and fix any issues plaguing your air conditioning system, ensuring cool relief on even the hottest days.
- AC Replacement: Upgrade to a more efficient and reliable AC unit with our expert replacement services, customized to suit your home’s unique cooling needs.
- AC Installation: Let us handle the installation of your new AC system, ensuring flawless setup for optimal performance and energy savings.
Heating Services
- Furnace Repairs: When your furnace is on the fritz, trust our team to deliver prompt and dependable repairs, restoring warmth and comfort to your home.
- Furnace Replacement: Upgrade to a high-efficiency furnace with our hassle-free replacement services, designed to improve comfort and lower energy costs.
- Furnace Installation: Our experts will ensure your new furnace is installed with precision and care, guaranteeing reliable heating for years to come.
- Fireplace Repairs: Keep cozy nights alive with our professional fireplace repair services, ensuring safe and efficient operation for your home’s focal point.
Additional Services
- Hot Water Heaters: Enjoy uninterrupted hot water with our comprehensive heater services, including installation, repairs, and maintenance tailored to your needs.
- Heat Pumps: Experience year-round comfort with our heat pump solutions, expertly installed and serviced to maintain optimal indoor temperatures.
- Indoor Air Quality: Breathe easier with our indoor air quality solutions, from air purifiers to ventilation systems, ensuring fresh and clean air throughout your home.
- Thermostat Installation: Take control of your comfort with a new thermostat installation, featuring the latest smart technology for convenient temperature management.
Elevate Your Home Comfort Today!
At Sears Heating and Cooling, we’re more than just HVAC experts; we’re your trusted partners in creating a comfortable and inviting home environment. Experience the difference with Sears Heating and Cooling—your comfort is our priority.
Ready to elevate your home’s comfort? Contact us today at 614-475-1800 or get in touch with us online to schedule service.
Recent Jobs and Reviews in Blacklick, OH
Our Local Reviews by City
- Blacklick, OH (2)
- Columbus, OH (171)
- Delaware, OH (2)
- Dublin, OH (16)
- Gahanna, OH (2)
- Galena, OH (8)
- Galloway, OH (3)
- Grove City, OH (5)
- Groveport, OH (1)
- Hilliard, OH (5)
- Johnstown, OH (1)
- Lewis Center, OH (3)
- Marble Cliff, OH (2)
- New Albany, OH (10)
- Plain City, OH (2)
- Powell, OH (7)
- Reynoldsburg, OH (1)
- Upper Arlington, OH (2)
- West Jefferson, OH (1)
- Westerville, OH (45)
- Worthington, OH (7)
Job Locations and Reviews
Responded to fallen lineset. Found straps to lineset broke. Rehung lineset with metal strap. Placed another layer of insulation around strap to prevent hole from wearing into line. Cycled system on unit ran with 22 degree deltat for 10 minute test time with no issues. No codes thrown. Performed first furnace check ip on 23 furnace. Set high pressure to 3.5inwc 7%o2. 24 ppm co in flu. Set low gas pressure .55. 15%02 64 ppm co in flu. 0 ppm co in supply cleaned flame sensor. 45 ohm igntion. No issues at this time. Customer has had repeated issues with connex stat connecting to app. Per install manager will return Wednesday to warranty stat
Perofmred yearly maintenance and safety checks on 16 Bryant furnace. Found 11.7%o2. 14 ppm co in flu. 0 ppm co in supply. 48 degree deltat. Furnace cycledninto second stage running with 8.8%o2. 59 ppm co in flu. 0 ppm co in supply. 54 degree deltat.
Performed yearly maintenance and safety checks on 18 furnace. 12.09%o2. 15 ppm co in flu. 0 ppm co in supply. 46 degree deltat. 14-20-1 filter. Replaced #35wp. No issues found at this time.
Cost to replace Lennox furnace with Bryant two-stage variable speed furnace. Also cost to install heat pump that will get the $2000 tax credit.
Responded to no heat. High pressure switch issue. Found water in inducer motor. Dirty trap. Advised hf3 for cleaning trap and assess from there. Customer accepted. Cleaned trap. Found furnace still wanting to kick off on pressure issue. Found flu termination reduced to 1.5. 80k btu furnace 50 equivalent ft of flu ran. On verge of of needing 3 Flu ran. Presented option hm12 to cut out reducer. Customer accepted. Included trap cleaning under flu repair. Cycled system on. Furnace ran properly in first stage. Switched into second without issue. Running roughly 15 minutes. 7.7%o2. 11 ppm co in flu. 0 in supply. 70RA 128 Sa 58 degree deltat.
Performed Yearly maintenance and safety checks on 2002 Bryant AC system. R22 system cleaned up installation as customer had concerns. Insulation is in good health tape was peeling. Found fan motor rusted running high amps. HC8 for repair. Not in stock advised could be 5-7 business days customer wants to get one more year from system and replace
Installed new system. Started heat pump. 11 degree subcooling. Stat would not connect to app. Advised customer servers may be down and to try tomorrow. If issues persist we can reevaluate
Sold ac to replace failing unit.
Ac maintenance
Found 24 year old Bryant condenser void of charge system is leaking. Technician provided multiple options for Bryant replacement at customers request
Customer stated there was a sound of gurgling from the furnace, found drain tube for condensation was not pushed into floor drain creating noise. Reinstall drain line and the floor drain no further issues at this time. On a Bryant furnace.
Failed capacitor on a Bryant air conditioner. Replaced failed component and added start assist to reduce synergy consumption and extent compressor lifetime
Scac
Performed yearly maintenance and safety checks on 2010 Bryant air-conditioning system. Found 45/5 voltage absorption system reading 39.9/4.8. Found 189–227 hard start reading 193. Clean 16254 filter. Customer is not interested in surge protection at this time.
Performed yearly maintenance and safety checks on 2020 Bryant air conditioning system. Found 40/5 voltage absorbed in system reading 40/5. 103.5 in Rush amps. Informed customer of surge protection customer will keep it in mind found 213 filter clean replaced last month. No issues found at this time
Performed yearly maintenance and safety checks on 2020 Goodman unit. Left new 1625 one filter. Found 45/5 voltage absorbs in system reading 44.5/5. 53 in Rush amps. No issues found at this point in time
Performed yearly maintenance and safety checks on 2018 Bryant AC system found 40/5 orange absorption system reading 38.4/4.9. 84.9 inrush amps. Replaced 14201 filter. No issues found.
Upon arrival thermostat in off position. Made call for heat. Furnace cycled on properly. Ran with 10.8%o2. 11 ppm co in flu. 0 ppm co in supply. Furnace faulted on limit. Found filter to be in backwards. Found white particulate on filter consistent with room humidifier. Customer has humidifier in child’s bedroom. Room has independent returns.
Upon arrival furnace in lockout. Clean filter. Reset furnace furnace failed to cycle first attempt. Upon second attempt furnace cycled on properly. Cycled furnace multiple times. Furnace failed to fault while present. Advised can quote for board or inducer as inducer still has noise issues. Customer wanting to get by this year and replace come fall Wanted ballpark numbers for new furnace as current furnace is in operation. Ballparked 4500-7000 for 80% and 5000-7500 for 90%. Furnace running upon departure.
Ac check
Replaced failed flame sensor on a Bryant furnace
Upon arrival customer closed technician noise recorded on phone. Found inducer noise upon start up. Excess noise detected but In working order. Blower motor Almost seized up completely. Extreme noise upon slow startup. After startup motor failed into stationary position. Called for pricing. In stock. Presented hc6 and hm9 to customer to address concerns. Customer chose option a for both repairs. Retrieved parts and performed repair. Cycled system 9.8%o2. 2 ppm co in flu 0 ppm co in supply. 50 degree dletat. No issues upon departure.
Thank you for the great review!
Thank you for the 5 star review!