Sears is proud to be the dependable name in Reynoldsburg, OH for everything heating and cooling related. Our highly-skilled professionals have what they need to tackle any job, diagnose any problem and complete any repair. Your comfort is our number one priority.
Find out why we’ve been held in such high esteem since we were founded in 1950. Read reviews from the good folks of Reynoldsburg, OH below.
Recent Jobs and Reviews in Reynoldsburg, OH
Our Local Reviews by City
- Blacklick, OH (2)
- Columbus, OH (171)
- Delaware, OH (2)
- Dublin, OH (16)
- Gahanna, OH (2)
- Galena, OH (8)
- Galloway, OH (3)
- Grove City, OH (5)
- Groveport, OH (1)
- Hilliard, OH (5)
- Johnstown, OH (1)
- Lewis Center, OH (3)
- Marble Cliff, OH (2)
- New Albany, OH (10)
- Plain City, OH (2)
- Powell, OH (7)
- Reynoldsburg, OH (1)
- Upper Arlington, OH (2)
- West Jefferson, OH (1)
- Westerville, OH (45)
- Worthington, OH (7)
Job Locations and Reviews

Diagnosed Goodman heat pump with R-410A refrigerant leak. Located fractured suction line at compressor connection due to vibration. Repaired connection, pressure tested system to 450 PSI with nitrogen, evacuated to 250 microns, and recharged to manufacturer specifications. Verified superheat at 12°F and subcooling at 10°F. Recommended installing vibration isolation pads and spring maintenance before cooling season begins.
Repaired Amana AMVC96 furnace with error code 5. Diagnosed failed pressure switch causing incomplete ignition sequence. Measured inducer motor current at 1.2A versus 0.8A specification. Replaced inducer assembly and verified proper condensate drainage. Static pressure tests confirmed adequate airflow across heat exchanger. Advised customer on annual maintenance schedule to prevent recurrence.

Installed new high-efficiency variable-speed split system for commercial client. System sized at 5 tons with 14 SEER rating. Performed nitrogen pressure test at 450 PSI, evacuated to 350 microns, and charged to manufacturer specs. Verified airflow at 400 CFM per ton. Advised client on programming economizer settings for spring temperature differentials.


Cost to install air conditioning and furnace. HVAC installation cost with 0% interest financing.


Secondary heat exchanger has failed in furnace. Cost to install furnace, air conditioner, and humidifier. 0% financing on furnace installation.
Working for our client in Reynoldsburg, OH, I performed yearly maintenance and safety checks on a 14-year-old Bryant furnace. I cycled the heat and recorded 6.9% O₂, 47 ppm CO in the flue, and 0 ppm CO in the supply, with a 47-degree Delta T. I replaced the 16x25x1 air filter, measured the ignition at 47 ohms, and cleaned the flame sensor and flue trap. No issues were identified during this inspection.
Furnace check
Responded to fireplace. Found no gas valve. Opened gas attempted to light fireplace. Flames erupted throughout fireplace opening. Flames 6-9 inches tall. Shut off gas and advised new incert need to be installed.
Performed yearly maintenance and safety checks on 17 rheem furnace. Found 10.93% o2. 52 ppm co in flu. 0 ppm Co in supply. 100 degree stack. Cleaned flame sensor blew out trap 7.5 voltage absorption system reading 7.3. Left new 16251 filter. No issues found at this time.
Performed yearly maintenance and safety checks on 2015 rheem furnace.customer replaced her own water panel. Blew out water trap. Cleaned flame sensor. 7.5 voltage absorption system reading 7.3. Made call for heat. Found 9.77%o2. 27 ppm co in flu 0 ppm co in supply. 55 degree deltat. Customer also inquired about water heater left quote. Will talk to husband and get with office to schedule if need be
Responded to no heat. Upon wiggling spark ignition furnace fired. Advised 1982 furnace will have obsolete components. Can leave quote. Furnace running upon departure. 25 ppm co in flu. 0 ppm co in supply. Left quote for new system.
Performed yearly maintenance and safety checks on 21 braynt furnace. Cleaned flame sensor and flu trap. 10.2%o2 46 ppm co in flu 52 degree deltat. Furnace cycled into second stage properly. Running with 55 degree deltat. 7.05%o2. 71 ppm co in flu. No issues found at this time.
Performed yearly maintenance and safety checks on 06 Goodman furnace. Cleaned flame sensor. 8.62%o2. 15 ppm co in flu. 0 ppm co in supply. Replaced 12241 filter. No issues at this time.
Yes Installed new 50 gallon water heater. Replaced ball valve shut off for water. Replaced tank. Flu is Properly drafting no leaks at water connections. No gas leaks at this time.
Customer had roto rooter outstated water coming from ac. Found pump full. Hard wired into board. Ground came loose. Sh3a to Resecured ground wire and test pump. Customer accepted. Pump cleared water. Found water dripping into floor from behind wall. Advised customer pump is working properly without issues. Additional issues behind wall. Pump drains into plumbing outside of wall. No water from pump/vinyl. Advised issues seem to be coming from inside wall/ behind sink.
Found blower seized up not operational. Motor is obsolete. Cannot find specs will need to remove blower and take in to compare for Universal motor.. advised no warranty comes with universal motors. Repair options would be HC12. cust9mer would rather put money into replacement. If filling out financing now. Left quote for 80%45k furnaces
Performed yearly maintenance and safety checks all 2023 AC no concerns at this time
May call for cooling upon arrival found outdoor unit cycled on compressor did not cycle, found voltage absorption system drained not providing assistance needed quoted HN13 customer chose option b to replace part with oem part and basic cleaning of condenser. Performed repair cycled system. 20 degree deltat upon departure.
HN13a


Cost to install air conditioning. Existing air conditioning is icing up that is due to low refrigerant. Cost to replace air condition.
Performed yearly maintenance and safety checks on 2021 Bryant AC system. Found 40/5 voltage absorption system reading 38.9/4.9. 72 in rush amps. Customer asked about humidifier water panel replacement, customer will replace humidifier panel themselves, has it been done since install advised to do it as soon as possible.
Made call for cooling compressor making horrible grinding type noise for roughly 1 second and then shutting off. Found 35/5 voltage absorption system within manufacture specifications. Proper voltage to unit. Found wire on bottom of contactor typically found on top. Switched wire. Compressor sounded slightly better ran for roughly 2-3 seconds before shutting down. Advised compressor damage has occurred. Will call tomorrow for quote on repair. Left new quote for 2.5 ton unit replacement customer will compare and contrast after quote.
Scac
Joel showed up on time and took care of my air conditioner. He told me there was a problem and got it fixed up fast. The unit is working well right now.